More Energy Efficient than Incandescent and most Halogen lamps
Low voltage DC operated
Instant light (less than 100 ns)
Superior ESD protection
Package Dimensions
Notes:
1.
Drawings not to scale.
2.
All dimensions are in millimeters.
3.
Tolerance is ±0.1mm unless otherwise noted.
4.
Protruded resin under flange is 1.0mm max.
5.
Lead spacing is measured where the leads emerge from the package.
6.
Specifications are subject to change without notice.
7.
Precautions for ESD:
STATIC SHIELD Electricity and surge damages the LED. It is recommended to use a wrist band or anti-electrostatic glove when handling the LED. All devices, equipment and machinery must be properly grounded.
Absolute Maximum Ratings at Ta=25℃
Parameter
Symbol
Max
Unit
Power Dissipation
PD
3
W
Pulse Forward Current
IPF
1000
mA
Forward Current
IF
700
mA
Reverse Voltage
VR
5
V
Operating Temperature Range
Topr
-40 to +85
℃
Storage Temperature Range
Tstg
-40 to +85
℃
Flux Characteristics at 700mA , Junction Temperature, TJ= 25℃
Color
Model
Min.(Lumen)
Typ.(Lumen)
White
H-HP803NW
70 lm
80 lm
Warm White
H-HP803WW
50 lm
60 lm
Blue
H-HP803NB
30 lm
40 lm
Pure Green
H-HP803PG
70 lm
90 lm
Amber
H-HP803NO
40 lm
50 lm
Red
H-HP803NR
60 lm
80 lm
Optical Characteristics at 700mA , Junction Temperature, TJ = 25℃
Color
CCT / λD
λ
λ/T
Min.
Typ.
Max.
White
5000K
6000K
7000K
--
--
Warm White
2850K
3300K
3800K
--
--
Blue
460nm
470nm
475nm
25
0.04
Cyan
490nm
505nm
515nm
30
0.04
Pure Green
520nm
530nm
540nm
35
0.04
Amber
587nm
590nm
595nm
20
0.05
Red
620nm
625nm
645nm
20
0.05
Electrical Characteristics at 700mA , Junction Temperature, TJ = 25℃
Color
Forward Voltage
/W Thermal Resistance,
Junction To Case
V/T
Min.
Typ.
Max.
White
3.4V
3.6V
4.0V
15
-2.0
Warm White
3.4V
3.6V
4.0V
15
-2.0
Blue
3.4V
3.6V
4.0V
15
-2.0
Pure Green
3.6V
3.8V
4.0V
15
-2.0
Amber
2.8V
3.0V
3.2V
18
-2.0
Red
2.8V
3.0V
3.2V
18
-2.0
NOTES:
1.
Minimum luminous flux or radiometric power performance guaranteed within published operating conditions. maintains a tolerance of ±10% on flux and power measurements
2.
Dominant wavelength is derived from the CIE 1931 Chromaticity diagram and represents the perceived color. maintains a tolerance of± 1 nm for dominant wavelength measurements.
3.
CCT ±5% tester tolerance.
Precautions For Use
▪
Over–current–proof
Customer must apply resistors for protection, otherwise slight voltage shift will cause