5050 SMD LED

1. Features
•  3 Chip high-luminosity SMD LED
•  5.4 x 5.0 x 1.6 mm (L x W x H), 6-Pin, Small Size Surface Mount Type
•  Wide Viewing Angle
•  Long Operating Life
2. Applications
• Automotive: Backlight in Dashboard and Switch
• Lighting Device: Indicator, General Lighting
• Camera Flash, Hand Carrier Flash
• General Use
3. Outline Drawing and Dimension
Notes:
1.  All dimensions are in millimeters
2.  All dimensions without tolerances are for reference only
4. Absolute Maximum Ratings ( Ta = 25 )
Parameter Symbol Value Unit

Power Dissipation

Pd

324

mW

Continuous Forward Current

IF

90

mA
Peak Forward Current ※1 IFP

300

mA

Operating Temperature

Topr

-30 ~ 85

Storage Temperature

Tstg

-40 ~100

Soldering Temperature

Tsol

260 (5sec)

※1 Duty ratio = 1/10, Pulse width = 0.1ms
5. Electro-optical Characteristics( Ta = 25 ℃ )

Parameter

Symbol

Conditions

Min.

Typ.

Max.

Unit.

Forward Voltage (per chip)

VF

IF = 20 mA

2.8

3.2

3.6

V

Reverse Voltage (per chip)

VR IR = 5 mA

0.7

0.8

1.5

V

Luminous Intensity※2 IV IF = 60 mA

4,000

-

8,000

mcd

Color Coordinates※3

CIE x
CIE y

IF = 60 mA

Refer to Color Coordinates Rank

 
Viewing Angle ※4

1/2

IF = 60 mA -

120

-

º

NOTES:
※2

Luminous Intensity is tested by a tester calibrated by CAS 140B(CIE LED_B) and has an accuracy of 10%

※3 Color Coordinates has an accuracy of   ±0.01.
※4 Viewing Angle is the angle until 50% of brightness measured from the front part of LED.

5.1 Luminous Intensity Rank 5.2 Forward Voltage Rank

Rank

Luminous Intensity (mcd)

C

4000 ~ 5000

D

5000 ~ 6000

E

6000 ~ 7000

F

7000 ~ 8000

Rank

Forward Voltage (V)

0

2.8 ~ 3.0

2

3.0 ~ 3.2

4

3.2 ~ 3.4

6

3.4 ~ 3.6

5.3 Color Coordinates Rank ( IF = 60 mA, Ta = 25 ℃ )

BW

CW

Rank Z1

Rank Z2

Rank  A1

Rank  A2

Rank B1

Rank B2

CIE x

CIE y

CIE x

CIE y CIE x CIE y CIE x CIE y

CIE x

CIE y

CIE x

CIE y

0.2400 0.2000 0.2500 0.2100 0.2600 0.2200 0.2700 0.2300

0.2800

0.2400

0.2900

0.2500

0.2400 0.2600

0.2500

0.2700

0.2600

0.2800 0.2700 0.2900 0.2800 0.3000 0.2900 0.3100
0.2500 0.2700 0.2600 0.2800 0.2700 0.2900 0.2800 0.3000 0.2900 0.3100 0.3000 0.3200
0.2500 0.2100

0.2600

0.2200 0.2700 0.2300 0.2800 0.2400 0.2900

0.2500

0.3000

0.2600

PW

Rank Y

Rank Z

Rank  A

Rank B

Rank C

CCT(K)

8000~7000

CCT(K)

7000~6500

CCT(K)

6500~6000

CCT(K)

6000~5500

CCT(K)

5500~5000

CIE x

CIE y

CIE x

CIE y

CIE x

CIE y

CIE x

CIE y

CIE x

CIE y

0.3092

0.2990

0.3540 0.3100 0.3625 0.3180 0.3692 0.3235 0.3762 0.3290

0.2870

0.3900

0.3655

0.4000

0.3775

0.4050 0.3872 0.4085 0.3970 0.4121

0.2995

0.4000

0.3775 0.4050 0.3872 0.4085 0.3970 0.4121 0.4080 0.4160
0.3540 0.3100

0.3625

0.3180 0.3692 0.3235 0.3762 0.3290 0.3840 0.3350

PW

 Rank J

Rank  K

Rank P

Rank Q

 Rank R

CCT(K)

3600~3400

CCT(K)

3400~3200

CCT(K)

3200~3000

CCT(K)

3000~2800

CCT(K)

2800~2600

CIE x

CIE y

CIE x

CIE y

CIE x

CIE y

CIE x

CIE y

CIE x

CIE y

0.3840

0.3350

0.3940

0.3433

0.4045 0.3500

0.4155

0.3550

0.4280

0.3600

0.4080

0.4160

0.4195

0.4200

0.4155

0.3550

0.4280

0.3600 0.4420 0.3650

0.4195

0.4200

0.4330

0.4248 0.4479

0.4295

0.4640

0.4335

0.4820

0.4365

0.3940

0.3433

0.4045

0.3500

0.4330

0.4248

0.4479

0.4295

0.4640

0.4335

6. Typical Characteristics Curves

7. Dimension of Tape / Reel

10. Reliability
10.1  Reliability Test Item

Test Items

Symbol
Value

High Temperature Storage

100℃, 1,000hr

0/25

Low Temperature Storage

-40℃, 1,000hr.

0/25

Temp. Humidity Storage

60℃, 90% RH,  1,000hr.

0/25

Steady State Operating life

25℃, 90mA , 1,000hr.

0/25

High Temperature
Operating Life

85℃, 30mA,  1,000hr

0/25

Low Temperature
Operating Life

-30℃, 60mA, 1,000hr.

0/25

Steady State Operating life
Of High Humidity Heat

60℃, 90% RH, 45mA, 1,000hr.

0/25

Thermal Shock

-40℃(30min)↔100℃(30min.), 100 cycle

0/20

ESD

HBM, 100 pF, 1.5 kohm, 3 times

0/20

10.2 Criteria for Judging the Damage

Parameters

Test Conditions

Criteria for judgment

Forward Voltage ( VF )

IF = 60 mA

Less than 110% of U

Luminous Intensity ( IV )

IF = 60 mA

> 70% of S


 * U means the upper limit of specified characteristics,  S means initial value.
Copyright (C) 2004 ISP All rights reserved.